Extreme durability & reliability, extra peace of mind.
Features
High durability & reliability
- Optimized internal air flow and thermal pattern by separation of HOT and COOL zone and professional air duct design.
- Continuous operation under 46°C ambient condition with more margin against tripping point.
Big touch color monitor
Sophisticated LCD interface enables you to see operation conditions at a glance.
Energy saving logic (AG series)
Automatically unloading if unload/load cycle is longer than setting time (30 seconds) and eliminates unnecessary pressure rise.
VS series ( Inverter model/[ A ]: Air cooled [ W ]: Water cooled )
Model | Discharge pressure | Discharge air flow |
Nominal output | Pipe connection | Fan motor | Lube oil quantity |
Noise level | Dimensions (W×D×H) |
Weight | |
---|---|---|---|---|---|---|---|---|---|---|
MPa | m3/min | cfm | kW | A | kW | L | dB (A) | mm | kg | |
VS110A/W | 0.75 | 21.4 | 756 | 110 | 80 | 1.8×2 (0.37) |
81 | 69 | 2,600× 1,600× 1,850 |
3,000 (2,900) |
VS110A/W-H | 0.85 | 20.2 | 713 | |||||||
VS110A/W-GH | 1.0 | 18.6 | 657 | |||||||
VS132A/W | 0.75 | 25.4 | 897 | 132 | 80 | 3.0×2 (0.37) |
81 | 70 | 2,600× 1,600× 1,850 |
3,250 (3,050) |
VS132A/W-H | 0.85 | 24.1 | 851 | |||||||
VS132A/W-GH | 1.0 | 21.4 | 756 | |||||||
VS160A/W | 0.75 | 30.3 | 1,070 | 160 | 80 | 3.0×2 (0.55) |
98 | 71 | 2,600× 1,600× 1,850 |
3,600 (3,250) |
VS160A/W-H | 0.85 | 28.8 | 1,017 | |||||||
VS160A/W-GH | 1.0 | 23.8 | 840 | 3,500 (3,150) |
||||||
VS200A/W | 0.75 | 37.3 | 1,317 | 200 | 100 | 4.0×2 (0.37) |
170 | 73 (72) |
3,060× 2,120× 2,150 |
4,900 (5,000) |
VS200A/W-H | 0.85 | 34.2 | 1,208 | |||||||
VS200A/W-GH | 1.0 | 31.1 | 1,098 | |||||||
VS250A/W | 0.75 | 43.4 | 1,533 | 250 | 100 | 4.0×2 (0.37) |
195 | 75 (72) |
3,060× 2,120× 2,150 |
5,300 (5,400) |
VS250A/W-H | 0.85 | 41.4 | 1,462 | |||||||
VS250A/W-GH | 1.0 | 38.6 | 1,363 |
Main motor: 4pole, TEFC induction motor, Class F, Inverter drive, Electrical spec: 380/415V, 50Hz
( ) for water cooled model"
AG series (Fixed speed model/[ A ]: Air cooled [ W ]: Water cooled )
Model | Discharge pressure | Discharge air flow |
Nominal output | Pipe connection | Fan motor | Lube oil quantity |
Noise level | Dimensions (W×D×H) |
Weight | |
---|---|---|---|---|---|---|---|---|---|---|
MPa | m3/min | cfm | kW | A | kW | L | dB (A) | mm | kg | |
AG110A/W | 0.75 | 21.4 | 756 | 110 | 80 | 1.8×2 (0.37) |
81 | 69 | 2,600× 1,600× 1,850 |
2,950 (2,850) |
AG110A/W-H | 0.85 | 20.2 | 713 | |||||||
AG110A/W-GH | 1.0 | 18.6 | 657 | |||||||
AG132A/W | 0.75 | 25.4 | 897 | 132 | 80 | 3.0×2 (0.37) |
81 | 70 | 2,600× 1,600× 1,850 |
3,150 (2,950) |
AG132A/W-H | 0.85 | 24.1 | 851 | |||||||
AG132A/W-GH | 1.0 | 21.4 | 756 | |||||||
AG160A/W | 0.75 | 30.3 | 1,070 | 160 | 80 | 3.0×2 (0.55) |
98 | 71 | 2,600× 1,600× 1,850 |
3,500 (3,150) |
AG160A/W-H | 0.85 | 28.8 | 1,017 | |||||||
AG160A/W-GH | 1.0 | 25.8 | 911 | |||||||
AG200A/W | 0.75 | 37.3 | 1,317 | 200 | 100 | 4.0×2 (0.37) |
170 | 73 (72) |
3,060× 2,120 × 2,150 |
4,900 (5,000) |
AG200A/W-H | 0.85 | 34.2 | 1,208 | |||||||
AG200A/W-GH | 1.0 | 31.1 | 1,098 | |||||||
AG250A/W | 0.75 | 43.4 | 1,533 | 250 | 100 | 4.0×2 (0.37) |
195 | 75 (72) |
3,060× 2,120× 2,150 |
5,300 (5,400) |
AG250A/W-H | 0.85 | 41.4 | 1,462 | |||||||
AG250A/W-GH | 1.0 | 38.6 | 1,363 |
Main motor: 4 pole, TEFC induction motor, Class F, Inverter drive, Electrical spec: 380/415V, 50Hz
( ) for water cooled model
* Suction conditions Absolute suction pressure: 1bar, Suction temperature: 20 °C, Humidity: 0%RH
* Discharge air volumes is converted to suction conditions.
* Discharge pressures are measured after gas coolers.
* Air produced by compressors should not be used in respiratory equipment furnishing air for direct inhalation.
* Noise values are based on the height of 1.0m and at the distance of 1.5m in front from the compressor package in anechoic chamber and under full-load operation.
* Since the cooling for the compressed air, lubricant, and the inside of the compressor unit depends on the surrounding air condition, the surrounding air must be properly ventilated to prevent the ambient temperature from rising above 40 °C.
* Specifications and descriptions are subject to change without notice.
* Weight values are based on 380V model.
* Please be sure to use KOBELCO genuine lubricants.