KOBELION VS/AG Series (Large Model)
KOBELION VS/AG Series (Large Model)
KOBELION VS/AG Series (Large Model)
KOBELION VS/AG Series (Large Model)
KOBELION VS/AG Series (Large Model)
KOBELION VS/AG Series (Large Model)

Extreme durability & reliability, extra peace of mind. 

Motor output : 110 - 250kW
Discharge air flow : 18.6 - 43.4 m3/min
Features

Features

High durability & reliability

  • Optimized internal air flow and thermal pattern by separation of HOT and COOL zone and professional air duct design.
  • Continuous operation under 46°C ambient condition with more margin against tripping point.
High durability & reliability

Big touch color monitor

Sophisticated LCD interface enables you to see operation conditions at a glance.

Big touch color monitor

Energy saving logic (AG series)

Automatically unloading if unload/load cycle is longer than setting time (30 seconds) and eliminates unnecessary pressure rise.

Energy saving logic
Specification

VS series ( Inverter model/[ A ]: Air cooled [ W ]: Water cooled )

Model Discharge pressure Discharge
air flow
Nominal output Pipe connection Fan motor Lube
oil quantity
Noise level Dimensions
(W×D×H)
Weight
MPa m3/min cfm kW A kW L dB (A) mm kg
VS110A/W 0.75 21.4 756 110 80 1.8×2
(0.37)
81 69 2,600×
1,600×
1,850
3,000
(2,900)
VS110A/W-H 0.85 20.2 713
VS110A/W-GH 1.0 18.6 657
VS132A/W 0.75 25.4 897 132 80 3.0×2
(0.37)
81 70 2,600×
1,600×
1,850
3,250
(3,050)
VS132A/W-H 0.85 24.1 851
VS132A/W-GH 1.0 21.4 756
VS160A/W 0.75 30.3 1,070 160 80 3.0×2
(0.55)
98 71 2,600×
1,600×
1,850
3,600
(3,250)
VS160A/W-H 0.85 28.8 1,017
VS160A/W-GH 1.0 23.8 840 3,500
(3,150)
VS200A/W 0.75 37.3 1,317 200 100 4.0×2
(0.37)
170 73
(72)
3,060×
2,120×
2,150
4,900
(5,000)
VS200A/W-H 0.85 34.2 1,208
VS200A/W-GH 1.0 31.1 1,098
VS250A/W 0.75 43.4 1,533 250 100 4.0×2
(0.37)
195 75
(72)
3,060×
2,120×
2,150
5,300
(5,400)
VS250A/W-H 0.85 41.4 1,462
VS250A/W-GH 1.0 38.6 1,363

Main motor: 4pole, TEFC induction motor, Class F, Inverter drive, Electrical spec: 380/415V, 50Hz
( ) for water cooled model"

AG series (Fixed speed model/[ A ]: Air cooled [ W ]: Water cooled )

Model Discharge pressure Discharge
air flow
Nominal output Pipe connection Fan motor Lube
oil
quantity
Noise level Dimensions
(W×D×H)  
Weight
MPa m3/min cfm kW A kW L dB (A) mm kg
AG110A/W 0.75 21.4 756 110 80 1.8×2
(0.37)
81 69 2,600×
1,600×
1,850
2,950
(2,850)
AG110A/W-H 0.85 20.2 713
AG110A/W-GH 1.0 18.6 657
AG132A/W 0.75 25.4 897 132 80 3.0×2
(0.37)
81 70 2,600×
1,600×
1,850
3,150
(2,950)
AG132A/W-H 0.85 24.1 851
AG132A/W-GH 1.0 21.4 756
AG160A/W 0.75 30.3 1,070 160 80 3.0×2
(0.55)
98 71 2,600×
1,600×
1,850
3,500
(3,150)
AG160A/W-H 0.85 28.8 1,017
AG160A/W-GH 1.0 25.8 911
AG200A/W 0.75 37.3 1,317 200 100 4.0×2
(0.37)
170 73
(72)
3,060×
2,120 ×
2,150
4,900
(5,000)
AG200A/W-H 0.85 34.2 1,208
AG200A/W-GH 1.0 31.1 1,098
AG250A/W 0.75 43.4 1,533 250 100 4.0×2
(0.37)
195 75
(72)
3,060×
2,120×
2,150
5,300
(5,400)
AG250A/W-H 0.85 41.4 1,462
AG250A/W-GH 1.0 38.6 1,363

Main motor: 4 pole, TEFC induction motor, Class F, Inverter drive, Electrical spec: 380/415V, 50Hz
( ) for water cooled model

* Suction conditions Absolute suction pressure: 1bar, Suction temperature: 20 °C, Humidity: 0%RH
* Discharge air volumes is converted to suction conditions.
* Discharge pressures are measured after gas coolers.
* Air produced by compressors should not be used in respiratory equipment furnishing air for direct inhalation.
* Noise values are based on the height of 1.0m and at the distance of 1.5m in front from the compressor package in anechoic chamber and under full-load operation.
* Since the cooling for the compressed air, lubricant, and the inside of the compressor unit depends on the surrounding air condition, the surrounding air must be properly ventilated to prevent the ambient temperature from rising above 40 °C.
* Specifications and descriptions are subject to change without notice.
* Weight values are based on 380V model.
* Please be sure to use KOBELCO genuine lubricants.